U16U-G4010
- SCSI to SCSI RAID subsystem
- Highest density in 3U rack space - support for sixteen 3.5-inch hard drives
- Auto switch cache policy and auto shutdown
- High array availability of drives across channels or enclosures
- Up to 64TB capacity per logical drive (LD) (OS dependent)
Configuration | Model | Form Factor |
---|---|---|
Single |
U16U-G4010-4 U16U-G4010-6 |
3U Rackmount |
Specifications
RAID
System Components
- Multiple arrays configurable with dedicated or global hot spares
- RAID levels supported: RAID 0, 1 (0+1), 3, 5, 10, 30, 50, NRAID, and JBOD
-
Online expansion by
- Adding new drives
- Copying and replacing drives with drives of larger capacity
- Automatic background rebuild
- Configurable stripe size and write policy per array
- Intelligent Drive Handling
-
In degraded mode: Skips irreparable blocks to continue rebuild
- In normal operation: Data block verification and repair
- Task Scheduler: Hands-free Media Scan maintenance
Redundant, hot-swappable components, designed for no single point of failure
- 3U RAID enclosure
- Single RAID controller
- Sixteen drive trays
- Dual redundant power supplies
- Two hot-swappable cooling fan modules
Management
- Java-based GUI RAID manager
- Centralized management of multiple arrays over in-band SCSI or Ethernet
- Event notification: email, LAN broadcast, fax, SMS, MSN, ICQ, or SNMP traps
- Auto on-lining of cascaded enclosures
- Enclosure status report through an I2C link connection
- SNMP 2.0 MIBs with get and set commands
- Firmware-embedded utility via LCD keypad or RS-232C terminal
Drive Interface
- 3.5", 1" high SCSI-320 disk drives
- 16 hot-swappable drive trays
- Automatic bad sector reassignment
- Drives hot-swappable via SCA-II connectors
- Dual channels across sixteen drives within each enclosure
Host Interface
- G4010-4: 2 VHDCI 0.8mm SCSI
- G4010-6: 4 VHDCI 0.8mm SCSI (two configurable as host or drive)
- Concurrent I/O commands
- Tagged Command queuing up to 256
- Variable stripe size per logical drive
- Optimization setting for random or sequential I/Os
Maintenance & Availability
- Optional Li-ION battery support
- Immediate array availability
- Drive roaming, array configuration on drives
- Auto Switch Cache Policy and Auto Shutdown
When a RAID controller detects conditions exceeding preset thresholds, the subsystem automatically flushes cached data and switches the array’s caching mode from write-back to write-through.
All environmental thresholds associated with this mechanism are user-configurable; the caching mode changes back to write-back once normal conditions are restored.
Physical/Electrical
Interfaces
- Two (G4010-4) or Four (G4010-6) VHDCI 0.8mm connectors
- One DB-9 RS-232C serial port (38400, n, 8, 1)
- One RJ-45 Ethernet port
Power Supply
- Two redundant, hot-swappable power supplies with PFC
- Input: 90 to 260VAC, 47 to 63Hz
- Output: +5V, 25A max.; +12V, 32A max.; +3.3V, 20A max.; 460 Watt capacity
Cooling Module
Four cooling fans in two separate modules
Environmental Specifications
Operating temperature | 5 to 40° C |
---|---|
Non-operating temperature | - 40º to 60ºC |
Relative humidity | 10 to 95%, non-condensing |
Operating altitude | sea level to 10,000ft |
Dimensions
- Chassis dimensions: 131H x 446.2W x 500D mm
- (w/ protrusions): 131H x 485W x 532D mm
- Package dimensions: 476H x 592W x 695D mm
System Weight (w/o drives)
- Net weight: 19kg
- Gross weight: 32.5kg